Case Study: Plastic Pipe Joint Repair Leaking in Confined Attic Space
A homeowner in the United Kingdom makes a DIY repair to a plastic pipe in the confined attic space of their house. The pipe was leaking through a joint where solvent cement bonding two sections together had failed, allowing water to escape and saturate the surrounding wooden floor.
Case Study Overview
Site Domestic property
Location United Kingdom
Repair Type No pressure pipe repair
Defect Plastic pipe leaking because of solvent cement failure
Repair Products
Sylmasta AB Original Epoxy Putty, SylWrap HD Pipe Repair Bandage,
Case Study PDF

Attic Plastic Pipe Leak Repair Case Study Details
The plastic pipe was located in a confined attic space in the roof of the house which could only be reached through a small hole in the ceiling. Solvent cement bonding two sections of pipe together had weakened and failed, allowing water to escape and saturate the surrounding wooden floor as a result.


When solvent cement joints fail, the most common repair method is cutting out and replacing the leaking section. This was not an option for the homeowner, however, because of the lack of room to access the pipe inside the loft and the joint being located next to a 90-degree elbow.
The homeowner contacted Sylmasta for pipe repair advice. We recommended using Sylmasta AB Original Epoxy Putty to encompass the leaking joint all the way around its diameter with a watertight material.
AB Original was chosen for its wet surface adhesion properties and its extended two-hour work time. It gave the homeowner longer to mix, shape and apply the epoxy putty without the worry of it curing off before application was completed, which would have been the case with a faster-setting epoxy putty like Superfast Aqua PW


The homeowner mixed AB Original until it was a streak free, uniform white colour. They formed the mixed putty into a long ‘sausage’ and wrapped it around the joint, pressing and smoothing it firmly down onto the surface of the pipe using a little water as they went.



AB Original easily formed a permanent bond with the plastic. This process was repeated several times using three AB Original ‘sausages’ until the entire joint was completely covered.
It left the leak area surrounded by a ring of epoxy putty, sealing the joint and addressing the failure of the solvent cement.
After applying AB Original, the homeowner reinforced the repair by overwrapping with SylWrap HD Pipe Repair Bandage. SylWrap HD was activated with water and wrapped around the joint whilst AB Original remained slightly tacky and soft.



SylWrap HD forced the epoxy putty as tightly as possible against the joint for an even more effective seal. The bandage cured within minutes to create a rock-hard, impact resistant sleeve strengthening the repair.
The homeowner completed the application in under 45 minutes. AB Original and SylWrap HD provided a quick, easy repair method compared with trying to remove and replace the leaking section of plastic pipe in such a small work area.
Products Used
AB Original Epoxy Putty Stick
Epoxy putty with high wet surface adhesion and a longer work time for careful application
SylWrap HD Bandage
Composite repair bandage which reinforces repairs by creating a rock-hard protective shell
Related Case Studies
Case Study: Leaking 3 Bar 300mm Steel Methanol Pipe Repair at Saudi Arabia Chemical Plant
Case Study: Major Pipe Repair & Strengthening Programme at Mexico Wastewater Treatment Plant
Case Study: Hospital Maintenance Team Seal 80mm Diameter Hole in Cast Iron Wastewater Drain Pipe
Case Study: Underwater Gas Pipe Network Exposed by Scour Repair & Protection Programme
Case Study: Homeowner DIY Repair of 25mm Lead Water Pipe Leaking Inside House Wall
Case Study: Cast Iron Waste Pipe U-Bend Crack Repair Above Hospital Corridor
Case Study: SylWrap Leaking Pipe Repair Passes ASME PCC-2 402-III Qualification Standard
Case Study: UAE Complex Approves SylWrap for Chilled Water District Cooling System Pipe Repair
Case Study: Repair of Underground Clay Drainage Pipe Cracked During Building Work