Gaps in a relatively new concrete flood defence wall at a multimillion pound dam in Scotland are sealed by a civil engineering company using AB Original Epoxy Putty
Tag: AB Original
Case Study: Rotted Wood Beam Repair in Renovation of Welsh Home
Large voids in a rotted wooden beam are filled to create a flat, smooth surface enabling the outside of a house to be rendered as part of a home renovation project
Case Study: Pipe Joints Sealed in Cast Iron Rainwater Stack Repair at London Office Block
300 pipe joints in a 250-metre-long internal cast iron rainwater stack suffering with corrosion are sealed, avoiding a total system replacement during the refurbishment of an office block
Case Study: Underground 600mm Concrete Water Main Pipe Break Repair in Canada
A city authority in Canada repair a break in an underground 600mm diameter concrete pipe at the exact point it passed through a wall, significantly reducing levels of water loss
Case Study: Seawater Storage Tank Floor Repair at Gas Processing Plant in Saudi Arabia
Gaps which had developed between rubber sheets covering the floor of a seawater storage tank at a gas plant are filled in to protect the exposed concrete coating the bottom of the tank
Case Study: Environment Agency Repair Crack in Underwater Wall Between River & Trout Farm
The Environment Agency permanently seal a 700mm long crack in an underwater wall discovered when abnormal levels of water were monitored passing from a river into a trout farm
Case Study: Fence Spurs Suffering from Concrete Cancer Filler Repair Using Epoxy Putty
Spurs suffering from concrete cancer which began disintegrating during the replacement of a trellis fence are repaired and rebuilt using Sylmasta AB Original Epoxy Putty
Case Study: Repair of Leaking 350mm Effluent Pipe Running out to Sea Underneath Salt Marshes
An effluent pipe running under salt marshes and out to sea is sealed in a logistically challenging repair which had to be completed in an eight hour window whilst the tide was out
Case Study: Reinforcement of Heavily Corroded Steel Pipe to Avoid Future Leak Repair
A heavily corroded section of steel pipe is reinforced, helping a site to avoid a future breach which would have required a costly and disruptive leak repair or replacement of the line
Case Study: Oil Refinery Repair of a Leaking Underground GRP Seawater Return Pipe
A leaking underground 3000mm GRP seawater return line is partially excavated and sealed in an epoxy putty repair at an oil refinery, cutting downtime from several weeks to two days