A landfill site in Wales encapsulates a pipe stub and flange plate after capping to ensure a decommissioned drainage system could not release toxic leachate into the environment
Tag: SylWrap HD
Case Study: Repair of Leaking 350mm Effluent Pipe Running out to Sea Underneath Salt Marshes
An effluent pipe running under salt marshes and out to sea is sealed in a logistically challenging repair which had to be completed in an eight hour window whilst the tide was out
Case Study: Live Leak Pipe Repair of Above and Below Ground Water Supply Pipelines in Libya
Water pipes located above and below ground as part of a network servicing a town in Libya required live leak repair to seal cracks without disrupting supplies
Case Study: Leaking Hydrogen Line Pipe Repair at Power Station in Puerto Rico
Leaking joints at either end of a hydrogen line installed as part of a new cooling system for a Puerto Rico power station required sealing before the pipe went into full service
Case Study: Reinforcement of 6 Metres of Corroded Steel Pipe in a Fire Station Pumping House
A 6 metre section of 150mm steel pipe including two 90 degree elbow bends at a fire station pump house is reinforced with SylWrap HD after being badly weakened by corrosion
Case Study: Repair of a Leaking 150mm Steel 90 Degree Elbow Bend at a Quarry Wash Plant
When a quarry in the UK could not fit a pipe repair clamp around a leaking 150mm steel 90 degree elbow bend, they instead used a SylWrap Pipe Repair Kit to seal the line
Case Study: Energy Company Make Live Leak Repair to District Heating System Steel Pipe
A steel pipe suspended in the ceiling of a building as part of a district heating system undergoes a live repair after a pinhole leak began causing substantial water damage
Case Study: Repair of a Cracked 90-year-old 70mm Malleable Iron Water Supply Pipe
With replacement fittings for a cracked 90-year-old malleable iron pipe no longer manufactured because of its age, a repair solution was needed to avoid replacing the entire line
Case Study: Live Leak Contaminated Water Pipe Repair at a Wastewater Treatment Plant
Catastrophe was averted at a Wastewater Treatment Works in the UK thanks to a live leak repair carried out after a contaminated water pipe was mistakenly cut through
Case Study: Snapped Nozzle on a 1500mm Seawater Cooling Line Repair & Reinforcement
The main supply line in a seawater cooling system undergoes urgent repair and reinforcement after a snapped nozzle began discharging water 5 metres into the air